EasyManuals Logo
Home>Hiwin>Servo Drives>E1 Series

Hiwin E1 Series Manual

Hiwin E1 Series
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
E1 Series Servo Drive Thunder Software Operation Manual Servo Drive Configuration
HIWIN MIKROSYSTEM CORP. 4-91
MD12UE01-2012
(3)
Start STABS tune
Execute STABS tune.
(4)
Display electrical angle
Display the commands and the feedback electrical angle in the test process.
Follow the procedure below to execute STABS tune.
After selecting STABS test/tune in Step2. block, select the range of pole pair pitch and click Start. Wait
until Tuned lights up in green.
Figure 4.6.3.2.2
4.6.3.3 Digital hall
This method uses hall sensor and rotor’s electrical angle to stably complete phase initialization.
Important
If the hall sensor’s information has been included in motor setup, Digital hall will be
automatically completed in phase initialization setting page, so users can skip this step.
Figure 4.6.3.3.1