EasyManuals Logo

HP ProLiant DL580 Generation 2 User Manual

HP ProLiant DL580 Generation 2
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Removal and Replacement Procedures
6. Remove the battery (part number 153099-001) from the system board.
Figure 2-50: Removing the battery from the system board
Reverse steps 1 through 6 to replace the battery.
CAUTION: Loss of BIOS settings occurs when the system battery is removed. BIOS settings
must be reconfigured whenever the battery is replaced. Power up the server and run RBSU.
2-64 HP ProLiant DL580 Generation 2 Server Maintenance and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL580 Generation 2 and is the answer not in the manual?

HP ProLiant DL580 Generation 2 Specifications

General IconGeneral
Processor SocketSocket 604
Storage ControllerIntegrated Smart Array 6i Controller
StorageSAS
NetworkIntegrated Dual Gigabit NICs
RAID SupportRAID 0, 1, 5
Expansion Slots6 PCI-X slots
Power SupplyRedundant Power Supplies
Form Factor4U Rack
ManagementHP Integrated Lights-Out (iLO)
Operating System SupportWindows Server, Linux
ProcessorIntel Xeon (up to 4 processors)
Drive BaysUp to 6 hot-plug SCSI or SAS drives