Removal and Replacement Procedures
HP ProLiant DL580 Generation 2 Server Maintenance and Service Guide 2-71
Re-entering the Server Serial Number
After replacing the system board or clearing the NVRAM, the server serial number must be
re-entered.
1. During the server startup sequence, press the F9 key to access RBS
U.
2. Select the System Options menu.
3. Select Serial Number. The following wa
rning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press
the Escape key to exit RBSU.
7. Press the F10 key to confir
m exiting RBSU. The server will automatically reboot.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL580 Generation 2 and is the answer not in the manual?

HP ProLiant DL580 Generation 2 Specifications

General IconGeneral
BrandHP
ModelProLiant DL580 Generation 2
CategoryServer
LanguageEnglish

Related product manuals