Figure 22. LM25 Field weakening speed
This parameter is not applicable to PM synchronous motors and therefore will not appear.
LM26 Motor Ls Max
This parameter is not applicable to Induction motors and therefore will not appear.
Maximum motor inductance.
This value can be learned with a motor tune.  Refer to section Motor Learn for
further information.
LM27 Motor Inductance Mode
This parameter is not applicable to Induction motors and therefore will not appear.
This parameter selects the relationship between the motor rated and maximum
inductances. It is determined by the drive and is used as part of the LL05 SPI function. If
the LM01 Motor Tune has been completed, this parameter should not need adjustment
and is only available for advanced troubleshooting.
This value can be learned with a motor tune.  Refer to section Motor Learn for
further information.