Parameter Descriptions
© 2024 KEB America, Inc.
233
FB31 PDO2 Data
Actual value of Process Data Output 2.
FB32 PDO3 Data
Actual value of Process Data Output 3.
FB33 PDO4 Data
Actual value of Process Data Output 4.
8.15.8 PDI Data
The PDI Data is the actual raw data received from the controller and mapped to the
functions according to the FB17-20 PDI Map Assignments. The data displayed is the raw
data before being masked, scaled by parameters FB05-09, then processed by the drive
in FB01-04.
FB34-FB37 Parameter Data
Motor Type
Range
Units
Default
Pass
Level
Ind.
PM
Min.
Max.
Imp.
Met.
RO
RO
-2147483647
2147483647
-
-
0
Basic
FB34 PDI1 Data
Actual Process Data Input 1 value from controller before Mask, Shift, or Multiplier.
FB35 PDI2 Data
Actual Process Data Input 2 value from controller before Mask, Shift, or Multiplier.
FB36 PDI3 Data
Actual Process Data Input 3 value from controller before Mask, Shift, or Multiplier.
FB37 PDI4 Data
Actual Process Data Input 4 value from controller before Mask, Shift, or Multiplier.