LS06 Intermediate Speed 2
This speed setting uses the one floor speed profile settings LS30-35 and LS38 Correction
Distance.
Max. Value: US06 Contract Speed
Run Profile: One Floor Profile (Intermediate Speeds 1, 2) LS30-38
LS07 Intermediate Speed 3
This speed setting uses the emergency speed profile settings LS40-45 and LS47
Correction Distance.
Max. Value: US06 Contract Speed
Run Profile: Emergency Profile (Intermediate Speed 3) LS40-47
Intermediate Speed 3 uses the profile settings labeled as îšµEmergency Speedîš¶.
8.7.2 Special Function Speeds
LS08 Earthquake Speed
Run speed when selected by an input programmed for earthquake speed is activated
before the start of the run. The high speed, intermediate speed 1, intermediate speed 2,
and intermediate speed 3 selections are limited to this speed.
Max Value: 150 fpm