EasyManuals Logo
Home>Lenze>Control Unit>ECS series

Lenze ECS series User Manual

Lenze ECS series
483 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
Commissioning
Optimising the drive behaviour after start
Speed controller adjustment
6
143
EDBCSXA064 EN 3.2
Signal limitation
ƒ If the drive operates with the maximum torque, the speed controller operates
within the limitation.
ƒ The drive cannot follow the speed setpoint.
ƒ MCTRL_bMMax_b is set to TRUE.
Setting the I component
For selecting torque starting values the integral component of the speed controller can be
set externally (e.g. when using the brake control).
ƒ MCTRL_bILoad_b = TRUE
The speed controller accepts the value applied at MCTRL_nISet_a into its integral
component.
The value at MCTRL_nISet_a acts as a torque setpoint for the motor control.
ƒ MCTRL_bILoad_b = FALSE
The function is switched off.

Table of Contents

Other manuals for Lenze ECS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECS series and is the answer not in the manual?

Lenze ECS series Specifications

General IconGeneral
BrandLenze
ModelECS series
CategoryControl Unit
LanguageEnglish

Related product manuals