Parameter Name / value range / [default seng] Info
0x2D40:005
(P135.05)
Device ulisaon (i*t): Error response
(Device ulisat.: Error response)
Selecon of the response to be executed when the device overload
monitoring funcon is triggered.
Associated error code:
•
9090 | 0x2382 - I*t error
2 Trouble
4Error types ^ 139
3 Fault
0x2DDF:001 Axis informaon: Rated current
•
Read only: x.xx A
Display of the rated current of the axis.
6.2.12 Heatsink Temperature Monitoring
Parameter Name / value range / [default seng] Info
0x2D84:001
(P117.01)
Heatsink temperature
(Heatsink temp.: Heatsink temp.)
•
Read only: x.x °C
Display of the current heatsink temperature.
0x2D84:002 Heatsink temperature: Warning threshold
50.0 ... [80.0]* ... 100.0 °C
* Default seng depending on the size.
Warning threshold for temperature monitoring.
•
If the heatsink temperature exceeds the threshold set here, the inver-
ter outputs a warning.
•
The warning is reset with a hysteresis of approx. 5 °C.
•
If the heatsink temperature increases further and exceeds the non-
adjustable error threshold (100 °C), the inverter changes to the
"Fault" device status. The inverter is disabled and thus any further
operaon is stopped.
6.2.13 Life-diagnosis
The following parameters provide some informaon about the use of the inverter.
This includes the following informaon:
•
Operang and power-on me of the inverter/control unit
•
Operang me of the internal fan
•
Number of switching cycles of the mains voltage
•
Number of switching cycles of the relay
•
Number of short-circuits and earth faults that have occurred
•
Display of the number of "Imax: Clamp responded too oen" errors that have occurred.
Parameter Name / value range / [default seng] Info
0x2D81:001
(P151.01)
Life-diagnosis: Operang me
(Life-diagnosis: Operang me)
•
Read only: x s
Display showing for how long the inverter has been running so far "Oper-
aon enabled" device state).
0x2D81:002
(P151.02)
Life-diagnosis: Power-on me
(Life-diagnosis: Power-on me)
•
Read only: x s
Display showing for how long the inverter has been supplied with mains
voltage so far.
0x2D81:003
(P151.03)
Life-diagnosis: Control unit operang me
(Life-diagnosis: CU oper. me)
•
Read only: x ns
Display showing for how long the control unit has been supplied with
voltage so far. This includes the external 24-V supply and voltage supply
via USB module.
•
This also includes the me within which the control unit has only
been supplied with an external 24 V voltage.
0x2D81:004
(P151.04)
Life-diagnosis: Main switching cycles
(Life-diagnosis: Switching cycles)
•
Read only
Display of the number of switching cycles of the mains voltage.
0x2D81:005
(P151.05)
Life-diagnosis: Relay switching cycles
(Life-diagnosis: Relay cycles)
•
Read only
Display of the number of switching cycles of the relay.
0x2D81:006
(P151.06)
Life-diagnosis: Short-circuit counter
(Life-diagnosis: Short-circ.count)
•
Read only
Display of the number of short circuits that have occurred.
0x2D81:007
(P151.07)
Life-diagnosis: Earth fault counter
(Life-diagnosis: Earthfault count)
•
Read only
Display of the number of earth faults that have occurred.