EasyManuals Logo
Home>Lenze>Inverter>i55 Series

Lenze i55 Series User Manual

Lenze i55 Series
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Parameter Name / value range / [default seng] Info
0x2D40:005
(P135.05)
Device ulisaon (i*t): Error response
(Device ulisat.: Error response)
Selecon of the response to be executed when the device overload
monitoring funcon is triggered.
Associated error code:
9090 | 0x2382 - I*t error
2 Trouble
4Error types ^ 139
3 Fault
0x2DDF:001 Axis informaon: Rated current
Read only: x.xx A
Display of the rated current of the axis.
6.2.12 Heatsink Temperature Monitoring
Parameter Name / value range / [default seng] Info
0x2D84:001
(P117.01)
Heatsink temperature
(Heatsink temp.: Heatsink temp.)
Read only: x.x °C
Display of the current heatsink temperature.
0x2D84:002 Heatsink temperature: Warning threshold
50.0 ... [80.0]* ... 100.0 °C
* Default seng depending on the size.
Warning threshold for temperature monitoring.
If the heatsink temperature exceeds the threshold set here, the inver-
ter outputs a warning.
The warning is reset with a hysteresis of approx. 5 °C.
If the heatsink temperature increases further and exceeds the non-
adjustable error threshold (100 °C), the inverter changes to the
"Fault" device status. The inverter is disabled and thus any further
operaon is stopped.
6.2.13 Life-diagnosis
The following parameters provide some informaon about the use of the inverter.
This includes the following informaon:
Operang and power-on me of the inverter/control unit
Operang me of the internal fan
Number of switching cycles of the mains voltage
Number of switching cycles of the relay
Number of short-circuits and earth faults that have occurred
Display of the number of "Imax: Clamp responded too oen" errors that have occurred.
Parameter Name / value range / [default seng] Info
0x2D81:001
(P151.01)
Life-diagnosis: Operang me
(Life-diagnosis: Operang me)
Read only: x s
Display showing for how long the inverter has been running so far "Oper-
aon enabled" device state).
0x2D81:002
(P151.02)
Life-diagnosis: Power-on me
(Life-diagnosis: Power-on me)
Read only: x s
Display showing for how long the inverter has been supplied with mains
voltage so far.
0x2D81:003
(P151.03)
Life-diagnosis: Control unit operang me
(Life-diagnosis: CU oper. me)
Read only: x ns
Display showing for how long the control unit has been supplied with
voltage so far. This includes the external 24-V supply and voltage supply
via USB module.
This also includes the me within which the control unit has only
been supplied with an external 24 V voltage.
0x2D81:004
(P151.04)
Life-diagnosis: Main switching cycles
(Life-diagnosis: Switching cycles)
Read only
Display of the number of switching cycles of the mains voltage.
0x2D81:005
(P151.05)
Life-diagnosis: Relay switching cycles
(Life-diagnosis: Relay cycles)
Read only
Display of the number of switching cycles of the relay.
0x2D81:006
(P151.06)
Life-diagnosis: Short-circuit counter
(Life-diagnosis: Short-circ.count)
Read only
Display of the number of short circuits that have occurred.
0x2D81:007
(P151.07)
Life-diagnosis: Earth fault counter
(Life-diagnosis: Earthfault count)
Read only
Display of the number of earth faults that have occurred.
Diagnoscs and fault eliminaon
Diagnoscs parameter
Heatsink Temperature Monitoring