Parameter Name / value range / [default seng] Info
0x2859:008
(P515.08)
Modbus TCP/IP monitoring: Fault reacon by me-out
Master
(MBTCP monitoring: React t-out mast)
From version 04.00
For further possible sengs, see parameter
0x2D45:001 (P310.01). ^ 223
Selecon of the response if within the me set in 0x23B6:001 (P514.01)
no valid message has arrived at the Modbus master.
Associated error code:
33046 | 0x8116 - Modbus TCP master me-out
3 Fault
0x2859:009
(P515.09)
Modbus TCP/IP monitoring: Fault reacon by me-out
Keep alive
(MBTCP monitoring: Reac t-out kp-al)
From version 04.00
For further possible sengs, see parameter
0x2D45:001 (P310.01). ^ 223
Selecon of the response if within the me set in 0x23B6:002
(P514.02)no valid message has been wrien into the keep alive register.
Associated error code:
33047 | 0x8117 - Modbus TCP Keep Alive me-out
3 Fault
9.8.4 LED status displays
Informaon on the CIP status can be obtained quickly via the "MS" and "NS" LED displays on
the front of the inverter. In addion, the LEDs at the RJ45 sockets indicate the Ethernet con-
necon status.
The meaning of the "MS" and "NS" LEDs can be obtained from the following two tables.
LED "MS" (green/red) Module status Status/meaning
o Nonexistent The network opon is not supplied with voltage.
On (green)
Operaonal The network opon works correctly.
Blinking green
Standby The network opon is not congured completely or the conguraon is incorrect.
Blinking red
Major recoverable
fault
The network opon contains a correctable error.
on (red)
Major unrecoverable
fault
The network opon contains a non-correctable error.
Blinking green/red
Device self tesng The network opon executes a self-test.
LED "NS" (green/red) Network status Status/meaning
o No IP address The network opon is not supplied with voltage or has not received an IP address yet.
On (green)
Connected The network opon works correctly an has established a connecon to the master.
Blinking green
No connecons The network opon
works correctly,
has been assigned to an IP address,
has not been implemented into the network yet by the master.
Blinking red
Connecon meout A me-out has occurred.
on (red)
Duplicate IP The network opon cannot access the network (IP address conict).
Blinking green/red
Device self tesng The network opon executes a self-test.
Status displays at the RJ45 sockets
The LEDs at the RJ45 sockets indicate the connecon status to the network:
LED "Link" (green) Status/meaning
o No connecon to the network.
on
A physical connecon to the network is available.
LED "Acvity" (yellow) Status/meaning
o No data transfer.
on or ickers
Data is exchanged via the network.
Conguring the network
Modbus TCP
LED status displays
352