11.1.3 Device commands for parameter change-over
The inverter supports several parameter sets. The parameter set can be selected by means of
the device commands "Load parameter set 1" ... "Load parameter set 4".
DANGER!
Changed parameter sengs can become eecve immediately depending on the acvang
method set in 0x4046 (P755.00).
The possible consequence is an unexpected response of the motor sha while the inverter is
enabled.
If possible, only carry out parameter changes while the inverter is disabled.
Certain device commands or sengs which might cause a crical state of the drive behav-
iour can generally only be carried our when the inverter is inhibited.
Details
The "parameter change-over" funcon provides a change-over between four sets with dier-
ent parameter values for up to 32 freely selectable parameters. For details on the compilaon
of the parameters and seng of the value sets, see the chapter "Parameter change-over".
^ 464
The change-over via the device commands depends on the acvaon method set in 0x4046
(P755.00):
Acvaon method = 1 or 3: Change-over takes place immediately.
Acvaon method = 0 or 2: The respecve device command is only executed if the inver-
ter is disabled.
Parameter Name / value range / [default seng] Info
0x2022:007
(P700.07)
Device commands: Load parameter set 1
(Device commands: Load par. set 1)
For further possible sengs, see parameter
0x2022:001 (P700.01). ^ 418
1 = load value set 1 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4042/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter change-over ^ 464
0 O / ready
0x2022:008
(P700.08)
Device commands: Load parameter set 2
(Device commands: Load par. set 2)
For further possible sengs, see parameter
0x2022:001 (P700.01). ^ 418
1 = load value set 2 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4043/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter change-over ^ 464
0 O / ready
0x2022:009
(P700.09)
Device commands: Load parameter set 3
(Device commands: Load par. set 3)
For further possible sengs, see parameter
0x2022:001 (P700.01). ^ 418
1 = load value set 3 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4044/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter change-over ^ 464
0 O / ready
0x2022:010
(P700.10)
Device commands: Load parameter set 4
(Device commands: Load par. set 4)
For further possible sengs, see parameter
0x2022:001 (P700.01). ^ 418
1 = load value set 4 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4045/1...32.
Aer successful execuon, the value 0 is shown.
4Parameter change-over ^ 464
0 O / ready
11.1.4 Delete logbook
By means of the "Delete logbook" device command, all logbook entries can be deleted.
Parameter Name / value range / [default seng] Info
0x2022:015
(P700.15)
Device commands: Delete logbook
(Device commands: Delete logbook)
Seng can only be changed if the inverter is inhibi-
ted.
1 = delete all entries in the logbook.
0 O / ready
1 On / start
Related topics
4Logbook ^ 110
Addional funcons
Device Commands
Delete logbook
421