16.3 Parameter aribute list
The parameter aribute list in parcular contains some informaon required for reading and
wring parameters via network.
•
The parameter aribute list contains all parameters of the inverter.
•
The parameter aribute list is sorted by addresses (index:subindex) in ascending order.
How to read the parameter aribute list:
Column Meaning
Address Address of the parameter in the object directory. Format: index:subindex
If the parameter can also be accessed via keypad, the "Display Code" is given in addion in brackets.
Designaon Parameter name
Default seng Default seng of the parameter
Category Funconal assignment of the parameter, for example "motor control" or "CANopen".
Data type Data type of the parameter:
I8 1 byte, with sign
I16 2 bytes with sign
I32 4 bytes with sign
I64 8 bytes with sign
U8 1 byte without sign
U16 2 bytes without sign
U32 4 bytes without sign
U64 8 bytes without sign
REAL32 4 bytes oang point
STRING[xx] ASCII string (with character length xx)
OCTET[xx] OCTET string (with xx bytes)
IDX 4 bytes without sign. Is used specially for addressing parameters.
Factor Factor for data transmission via network, depending on the number of decimal posions:
1 No decimal posions
10 1 decimal posion
100 2 decimal posions
1000 3 decimal posions
10000 4 decimal posions
A Aributes (combinaons of several aributes also possible):
C Seng can only be changed if the inverter is inhibited.
E Value is displayed as IP address on the keypad.
H Value is displayed as hexadecimal value on the keypad.
I Parameter is not displayed.
K Parameter is only displayed on the keypad.
O Parameter can be recorded with the oscilloscope funcon.
P Seng is saved in the memory module.
X Parameter is not displayed in the engineering tools.
M Mapping:
r Receive mapping permissible.
t Transmit mapping permissible.
rt Receive and transmit mapping permissible.
- Mapping not permissible.
Parameter aribute list (short overview of all parameter indexes)
Address Designaon Default seng Category Data type Factor A M
0x1000 Device type - (Read only) CANopen U32 1 H -
0x1000 Device type - (Read only) EtherCAT U32 1 X -
0x1000 NMT_DeviceType_U32 - (Read only) POWERLINK U32 1 X -
0x1001 Error register - (Read only) CANopen U8 1 H t
0x1001 ERR_ErrorRegister_U8 - (Read only) POWERLINK U8 1 X -
0x1003:001 ERR_History_ADOM: ErrorEntry_DOM 1 - (Read only) POWERLINK U32 1 X -
0x1003:002 ERR_History_ADOM: ErrorEntry_DOM 2 - (Read only) POWERLINK U32 1 X -
* Default seng depending on the size. Firmware version 05.00.00.00
Appendix
Parameter aribute list
659