EasyManuals Logo
Home>Lenze>Inverter>i55 Series

Lenze i55 Series User Manual

Lenze i55 Series
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
5.4 Keypad parameter list
For commissioning or diagnoscs using the keypad, all parameters of the inverter that can
also be accessed by means of the keypad are listed in the following "Keypad parameter list".
The keypad parameter list is sorted in ascending order in compliance with the "display
code" (Pxxx).
In order to provide for quick access, all parameters of the inverter are divided into dier-
ent groups according to their funcon.
Group 0 contains the congurable "Favorites". In the default seng these are the most
common parameters for the soluon of typical applicaons. 4Favorites ^ 459
Based on the hundreds digit of the display code (Pxxx) you can quickly see in which group
the parameter is to be found on the keypad:
Parameter Group - name Descripon
P1xx Group 1 - Diagnoscs Diagnosc/display parameters for displaying device-internal process factors, cur-
rent actual values, and status messages.
4Diagnoscs parameter ^ 109
P2xx Group 2 - Basic seng Seng of the mains voltage, selecon of the control and setpoint source, starng
and stopping performance, frequency limits and ramp mes.
4Basic seng ^ 143
P3xx Group 3 - Motor control Conguraon of the motor and motor control
4Motor control ^ 163
P4xx Group 4 - I/O seng Funcon assignment and conguraon of the inputs and outputs
4Flexible I/O conguraon ^ 525
P5xx Group 5 - Network seng Conguraon of the network (if available)
4Conguring the network ^ 226
P6xx Group 6 - Process controller Conguraon of the process controller
4Conguring the process controller ^ 407
P7xx Group 7 - Addional funcons Parameterisable addional funcons
4Addional funcons ^ 417
P8xx Group 8 - Sequencer The "sequencer" funcon serves to dene a programmed sequence of speed set-
points, PID setpoints or torque setpoints for the motor control. Switching to the
next setpoint can be executed in a me-based or event-based manner.
4Sequencer ^ 504
A complete overview of all parameter indexes can be found in the annex in the
Parameter aribute list. ^ 659
Frequently used abbreviaons in the short keypad designaons of the parameters:
Abbreviaon Meaning
AI Analog input
AO Analog output
B0, B1, ... Bit 0, bit 1, ...
CU Control unit
DI Digital input
DO Digital output
LU Undervoltage
MOP Motor potenometer
NET Network
OU overvoltage
PID Process controller
PU Power unit
QSP Quick stop
Setp Setpoint
WD Watchdog
Commissioning
Keypad parameter list