7.9 Opcal device idencaon
For applicaons including several interconnected inverters it may be dicult to locate a device
that has been connected online. The "Opcal device idencaon" funcon serves to locate
the inverter by means of blinking LEDs.
Details
In order to start the visual tracking,
•
click the buon in the toolbar of the »EASY Starter« or
•
set 0x2021:001 (P230.01) = "Start [1]".
Aer the start, both LEDs "RDY" and "ERR" on the front of the inverter synchronously blink
very fast.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
Both LEDs are blinking in a very rapidly synchro-
nous mode
"Visual tracking" funcon is acve.
The blinking duraon can be set in 0x2021:002 (P230.02) or selected in the »EASY Starter« in
the dropdown list eld:
Parameter Name / value range / [default seng] Info
0x2021:001
(P230.01)
Opcal tracking: Start detecon
(Opcal tracking: Start detecon)
1 = start opcal device idencaon.
•
Aer the start, the two LEDs "RDY" and "ERR" on the front of the
inverter are blinking with a blinking frequency of 20 Hz for the blink-
ing duraon set in 0x2021:002 (P230.02). The seng is then automat-
ically reset to "0" again.
•
If the funcon is reacvated within the blinking me set, the me is
extended correspondingly.
•
A manual reset to "0" makes it possible to stop the funcon prema-
turely.
0 Stop
1 Start
0x2021:002
(P230.02)
Opcal tracking: Blinking duraon
(Opcal tracking: Blink. duraon)
0 ... [5] ... 3600 s
Basic seng
Opcal device idencaon