Parameter Name / value range / [default seng] Info
0x2632:004
(P411.04)
Inversion of digital inputs: Digital input 4
(DI inversion: DI4 inversion)
Inversion of digital input 4
0 Not inverted
1 Inverted
0x2632:005
(P411.05)
Inversion of digital inputs: Digital input 5
(DI inversion: DI5 inversion)
Inversion of digital input 5
0 Not inverted
1 Inverted
0x2632:006
(P411.06)
Inversion of digital inputs: Digital input 6
(DI inversion: DI6 inversion)
•
Only available for applicaon I/O.
Inversion of digital input 6
0 Not inverted
1 Inverted
0x2632:007
(P411.07)
Inversion of digital inputs: Digital input 7
(DI inversion: DI7 inversion)
•
Only available for applicaon I/O.
Inversion of digital input 7
0 Not inverted
1 Inverted
0x2633:001 Digital input debounce me: Digital input 1
1 ... [1] ... 50 ms
Debounce me of digital input 1
0x2633:002 Digital input debounce me: Digital input 2
1 ... [1] ... 50 ms
Debounce me of digital input 2
0x2633:003 Digital input debounce me: Digital input 3
1 ... [1] ... 50 ms
Debounce me of digital input 3
0x2633:004 Digital input debounce me: Digital input 4
1 ... [1] ... 50 ms
Debounce me of digital input 4
0x2633:005 Digital input debounce me: Digital input 5
1 ... [1] ... 50 ms
Debounce me of digital input 5
0x2633:006 Digital input debounce me: Digital input 6
1 ... [1] ... 50 ms
•
Only available for applicaon I/O.
Debounce me of digital input 6
0x2633:007 Digital input debounce me: Digital input 7
1 ... [1] ... 50 ms
•
Only available for applicaon I/O.
Debounce me of digital input 7
Example: Acvang two funcons simultaneously via digital input 4
The principle of assigning triggers to funcons also enables a digital input to be assigned to
several funcons. The wiring complexity is reduced since there is no necessity to interconnect
several digital inputs.
If, for instance, the frequency preset 1 is to be selected via the digital input 4 and a change-
over to the acceleraon me 2 and deceleraon me 2 is to take place at the same me, this
can be easily realised by the following parameter seng:
Parameter Name Seng for this example
0x2631:018 (P400.18) Acvate preset (bit 0) Digital input 4 [14]
0x2631:039 (P400.39) Acvate ramp 2 Digital input 4 [14]
In order to achieve the desired behaviour, the digital input 4 must not be
assigned to any further funcons!
Flexible I/O conguraon
Conguraon of digital inputs
596