15 Technical data
Maschinenfabrik Reinhausen GmbH 2020328 4453918/14 ENETOS
®
TD
Control cabinet ETOS® TD S ETOS® TD L ETOS® TD XL
Permitted ambient
temperature during
operation
Standard: -25...50°C
HiTemp: -25...+55°C
Storage temperature -25...+70°C
Degree of protection IP66
Potential corrosive-
ness category in ac-
cordance with
ISO12944-2:2018
C4 high, C4 very high
C5 high, C5 very high
CX
C4 high, C4 very
high, C5 high
Permissible total
weight
85kg 200kg
Table124: Technical data for the control cabinet
1
)Observe the information on the nameplate.
15.2.1 Connection terminals
Terminal block Maximum permitted operating voltage
X1 max. 250/440 VAC
X4 max. 250/440 VAC
X6 max. 24 VDC (SELV circuit)
X10 max. 250/440 VAC
Table125: Maximum permitted operating voltage of the connection terminals for external cir-
cuits