16 Rockwell Automation Publication 7000L-UM301F-EN-P - March 2020
Chapter 1 Overview of Drive
Benefits of the 7000L “C” Frame Liquid-cooled Drive:
Completely integrated MV drive package reduces customer installation
costs and start-up time.
Higher power rating capability (up to 9000 hp / 6715 kW)
18 Pulse and AFE rectifiers for low harmonic solutions that meet IEEE
519-1992 Harmonic Guidelines
Motor friendly current and voltage output waveforms for use with
standard new and existing motors
Inverter duty motors not required
Motor temperature derating not required
No additional dv/dt or peak voltage stress to motor insulation system
Tested up to 15 kilometers (9.3 miles) cable distance between drive and
motor
Spacious cable termination cabinet for ease of use by installation
contractor
Cable termination stabs accommodate:
3 cables in / 3 cables out (Direct-to-Drive™ or AFE rectifier)
9 cables in / 3 cables out (18 Pulse)
Top or bottom entry and exit of line and load cables
90% of drive losses are rejected outside the control room
Integral liquid-cooled DC link inductor reduces overall dimension and
eliminates external interwiring.
Integral pumping panel includes:
Line supply c/w disconnect and fusing
Closed loop coolant system
Iron and chloride free liquid ethyl-glycol / deionized water mixture
Low conductivity coolant (1-2 micro-Siemens / cm
3
)
Isolated from medium voltage
Fully serviceable low voltage compartment isolated from medium
voltage power
Monitors coolant temperature, flow, level, conductivity, and pressure
Redundant pumping system (optional)
Automatic pump change over on pump failure
1/2 turn valves with quick disconnect couplers for pump replacement
when drive is operating
Full drip tray to contain any spilled coolant
Drain and fill pump for convenient filling
Industrial schedule 80 CPVC piping for pump panel, headers and
manifolds (no condensation possibility)
Control hardware for cycling of main / redundant cooling pumps and
heat exchanger fans
“Plug and play” Power Cage concept
Central location for easy access to all main power components

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley PowerFlex 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley PowerFlex 7000 and is the answer not in the manual?

Rockwell Automation Allen-Bradley PowerFlex 7000 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley PowerFlex 7000
CategoryDC Drives
LanguageEnglish

Related product manuals