47
GATE/EXPANDER screen
GATE/EXPANDER screen
1.
Access the GATE/EXPANDER screen for the desired
channel.
2.
Press [FUNC] to access the GATE FUNCTION screen.
The operations available at the GATE FUNCTION screen are as
follows:
For information on, COPY, PASTE, UNDO, LIBRARY, or PEAK
CLEAR, go to “Basic operation,“ and refer to “Copy“ (p. 28),
“Paste“ (p. 29), “Undo“ (p. 29), “Library“ (p. 30), or “Peak clear“ (p.
33).
1.
Access the GATE FUNCTION screen.
2.
Select “TYPE SELECT“ and press [ENTER].
GATE TYPE SELECT screen appears.
3.
Select GATE, EXPANDER, or DUCKING as the GATE type,
and press [ENTER].
The type changes.
GATE FUNCTION screen
TYPE SELECT
This selects the type of gate from among the three
types of GATE, EXPANDER, and DUCKING (p. 45).
KEY-IN SOURCE This button accesses the KEY-IN SELECT screen for
selecting the key-in signal. For stereo-linked
channels, L and R sources are shown (p. 37).
KEY-IN FILTER This button accesses the GATE KEY-IN FILTER screen
(p. 48).
COPY Copies gate settings to the clipboard.
PASTE When gate settings have been copied to the
clipboard, this pastes the settings from the
clipboard.
UNDO This undoes the last-performed parameter paste
operation. It is not displayed when there is no action
to undo.
LIBRARY Accesses the GATE LIBRARY screen.
PEAK CLEAR Clears the level meter's peak hold or over indication.
Selecting the type of GATE/EXPANDER
M-200i_e.book 47 ページ 2013年1月16日 水曜日 午後4時9分