S
IMPLE
N
ETWORK
M
ANAGEMENT
P
ROTOCOL
3-51
- Retry times – The maximum number of times to resend an inform
message if the recipient does not acknowledge receipt. (Range: 0-255;
Default: 3)
• Enable Authentication Traps
1
– Issues a notification message to
specified IP trap managers whenever authentication of an SNMP request
fails. (Default: Enabled)
• Enable Link-up and Link-down Traps – Issues a notification message
whenever a port link is established or broken. (Default: Enabled)
Web – Click SNMP, Configuration. Enter the IP address and community
string for each management station that will receive trap messages, specify
the UDP port, trap version, trap security level (for v3 clients), trap inform
settings (for v2c/v3 clients), and then click Add. Select the trap types
required using the check boxes for Authentication and Link-up/down
traps, and then click Apply.
Figure 3-25 Configuring SNMP Trap Managers
CLI – This example adds a trap manager and enables authentication traps.
1.
These are legacy notifications and therefore when used for SNMP Version 3 hosts, they must be enabled
in conjunction with the corresponding entries in the Notification View (page 3-60).
Console(config)#snmp-server host 10.1.19.23 inform private
version 2c udp-port 160 4-129
Console(config)#snmp-server enable traps authentication 4-132
Console(config)#

Table of Contents

Other manuals for SMC Networks TigerSwitch SMC6128L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks TigerSwitch SMC6128L2 and is the answer not in the manual?

SMC Networks TigerSwitch SMC6128L2 Specifications

General IconGeneral
BrandSMC Networks
ModelTigerSwitch SMC6128L2
CategorySwitch
LanguageEnglish

Related product manuals