10.2.5 Malfunctions of systems for DF engine (XX33NN to XX39NN)
Tab 10-34 Gas concentration in piston underside is too high
Indication Possible cause Procedure
AE3315C There is a leakage in the gas sys-
tem
•
Find the cause and repair the defective
item.
Tab 10-35 Difference pressure of pilot fuel filter is too high
Indication Possible cause Procedure
PS3464A The pilot fuel filter is clogged
•
Replace the filter element.
Tab 10-36 Gas supply pressure is too low
Indication Possible cause Procedure
PT3901C The gas supply is defective
•
Find the cause and repair the fault.
The gas filter is clogged
•
Clean or replace the gas filter. For the filter
of the iGPR refer to [section not applicable
for this engine].
X92DF
AA00-0000-00AAA-410C-A
Operation Manual Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 523 - Issue 002 2020-08