Tab 10-60 Power supply to the power supply box E85 has a failure
Indication Possible cause Procedure
XS5056A The power supply is set to OFF
•
Set to ON the power supply.
The power supply system is de-
fective
•
Repair the power supply system.
Tab 10-61 Unwanted engine speed decrease
Indication Possible cause Procedure
The speed setting from the speed
control system is decreased or is
not in the specified limits
•
Do a check of the speed control system.
The fuel injection quantity from
the speed control system is de-
creased
•
A procedure is not necessary because the
control system prevents too much load in
heavy sea.
The fuel injection system is defec-
tive
•
Find the cause and repair the fault.
Tab 10-62 Unwanted engine stop
Indication Possible cause Procedure
The fuel injection system is defec-
tive
•
Find the cause and repair the fault.
This is a result of the malfunction
in Table 10-61 - Unwanted engine
speed decrease
•
Do the repair shown there.
There is heavy sea
•
Set to ON the heavy sea mode.
X92DF
AA00-0000-00AAA-410C-A
Operation Manual Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 530 - Issue 002 2020-08