DocuColor 12/DCCS50
15-371 X - Fail 6RAP, 15-380/15-381 / 15-382 / 15-383 /
Reissue
Status Indicator RAPs
15-371 X - Fail 6RAP
The control logic on the Pre IPS PWB detected a hardware failure.
Initial Actions
• Refer to BSD 6.7 in the following procedure:
• Ensure that P/J560 on t
he Pre IPS PWB and the BR PWB is fully seated.
Procedure
PO/PO the machine. If the fault continues, replace the following:
• Pre IPS PWB (PL 3.
5)
•BR PWB (PL 3.
5)
15-380/15-381 / 15-382 / 15-383 / 15-384 / 15-385 CCD AGC
Fail RAP
The Automatic Gain Control (AGC) for a specific channel from the CCD PWB failed.
15-380: CCD Channel 1 RED (odd) AGC Fail
15-381: CCD Channel 2 RED (even) AGC Fail.
15-382: CCD Channel 3 GREEN (odd) AGC Fail.
15-383: CCD Channel 4 GREEN (even) AGC Fail.
15-384: CCD Channel 5 BLUE (odd) AGC Fail.
15-385: CCD Channel 6 BLUE (even) AGC Fail.
Initial Actions
• Refer to BSD 6.1, BSD 6.2, and BSD 6.7 in the following procedure.
• Verify that the Platen Glass is installed correctly.
• Verify that the following NVM values match the Machine Configuration on the Platen or
the DA
DF: NVM715-125: 0=Platen, 1=DADF.
Procedure
Enter dC330 006-002 ITT Exposure Lamp. Press Start. The Exposure Lamp lights.
YN
Go to the 6-371 E
xpos
ure Lamp Fail RAP.
The Exposure Lamp lights at the correct intensity without flickering.
YN
Go to Fl
ag 1 on BS
D 6.1 and check the wires for an open or short circuit. Verify that P/
J535 on the Lamp Ballast PWB and P/J521 on the IIT Driver PWB are seated. If the wires
are connectors are OK, replace the following:
• Exposure Lamp (PL
3.
4)
• Lamp Ballast PWB (PL 3.
4)
• IIT Driver PWB (PL 3.2)
The White Reference Strip on the bottom of the Platen Glass (Platen top machines PL
3.1)
or underneath the Plate (PL 12.11) for DADF machines is clean and undamaged.
YN
Clean the White reference Strip or replace the Platen Glass (PL
3.1) or t
he Plate (PL
12.11) on DADF equipped machines.
Go to Flag 1 on BSD 6.2 and check the Flat Cable P/J510 on t
he Pre IPS PWB and P/J500 on
the CCD PWB for damage. Reseat the Flat Cable. If the problem continues, replace the follow-
ing:
• CCD PWB (PL
3.
2)
• Pre-IPS PWB (PL 3.
5)