1/05
6-47
DocuColor 12/DCCS50
dC131PH NVM List (761)
General Procedures
Reissue
dC131PH NVM List (761)
Table 1 PH NVM List (761)
Chain-
Link Nam
e Default Range Description
761-001 PRE FEED START
T
IMI
NG-TRAY1
590 565-615 #1 Tray: Time from Pre-Feed Start to
Regi-Feed (Except B side)
Default=1180ms
Range=±50ms (±25)
Unit=2ms/step
761-002 PRE FEED START
TIMING-
T
RAY1(PANEL B)
559 534-624 #1 Tray: Time from Pre-Feed Start to
Regi-F
eed (B side feed length: Less than
190mm (*))
Default=1118ms
Range=±50ms (±25)
Unit=2ms/step
Default DATA=559 (Quadrant
Mac
hi
ne CLOCK)
(*) Applied in the Nudger Roll 2-Drops
Mode
761-003 DOUBLE PRE
F
EED
START TIM-
ING-TRAY1
559 534-624 #1 Tray: Time from Pre-Feed Start to
Regi-F
eed (B side feed length: 190 mm or
longer (*))
Default=1118ms
Range=±50ms (±25)
Unit=2ms/step
(*) Applied in the Double Pre Feed Mode.
761-004 PRE FEED START
T
IMI
NG-TRAY2
710 685-735 #2 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1420ms
Range=±50ms (±25)
Unit=2ms/step
761-005 PRE FEED START
TIMING-
T
RAY2(PANEL B)
679 654-704 #2 Tray: Time from Pre-Feed start to
Regi-F
eed (B side)
Default=1358ms
Range=±50ms (±25)
Unit=2ms/step
761-006 PRE FEED START
TIMI
NG-TRAY3
810 785-835 #3 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1620ms
Range=±50ms (±25)
Unit=2ms/step
761-007 PRE FEED START
TIMING-
TRAY3(PANEL B)
779 754-804 #3 Tray: Time from Pre-Feed start to
Regi-F
eed (B side)
Default=1558ms
Range=±50ms
(±25)
Unit=2m
s/step
761-008 PRE FEED START
TIMI
NG-TRAY4
910 885-935 #4 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1820ms
Range=±50ms
(±25)
Unit=2m
s/step
761-009 PRE FEED START
TIMI
NG-
TRAY4(PANEL B)
879 854-904 #4 Tray: Time from Pre-Feed start to
Regi-F
eed (B side)
Default=1758ms
Range=±50ms
(±25)
Unit=2m
s/step
761-010 TRAY1 NUDGER
ROLL SO
LENOID
ON TIME
39 0-45 #1 Tray Pre-Feed: Nudger Roll SOL ON
ti
me
Default=390ms
Range=0-450ms (0 - 45)
Unit=10ms/step
Default DATA=39 (10ms RTMR)
761-011 TRAY2 NUDGER
ROLL SO
LENOID
ON TIME
39 0-45 #2 Tray Pre-Feed: Nudger Roll SOL ON
ti
me
Default=390ms
Range=0-450ms (0-45)
Unit=10ms/step
Default DATA=39 (10ms RTMR)
761-012 TRAY3 NUDGER
ROLL SO
LENOID
ON TIME
39 0-45 #3 Tray Pre-Feed: Nudger Roll SOL ON
ti
me
Unit=10ms/step
Default DATA=39 (10ms RTMR)
761-013 TRAY4 NUDGER
ROLL SO
LENOID
ON TIME
39 0-45 #4 Tray Pre-Feed: Nudger Roll SOL ON
ti
me
Unit=10ms/step
Default DATA=39 (10ms RTMR)
761-014 ADJUST TRAY 1
PRE FE
ED STOP
POSITION(FEED
ROLL 1 SPEED
300mm/s)
24 4-39 Time from #1 Feed Out SNR ON to #1
F
eed Motor OFF (Feed Roll 300mm/s -
Stop timing)
Default=48ms
Range=8-78ms (4-39)
Unit=2ms/step
Default DATA=24 (2ms RTMR)
Table 1 PH NVM List (761)
Ch
ain-
Lin
k Name Default Range Description