D21 15
2. Drive engine error codes correlation table
Error
codes/
Indicator
light
SID
S
PID
P
FMI
SPN
FMI
Explanation
QSK19
111
Red
S254
12
629
12
Engine control module-critical internal failure
X
112
Red
S020
7
635
7
Engine timing actuator has no response to ECM
instruction
X
113
Amber
S020
3
635
3
Engine timing actuator circuit-voltage above
normal, or shorted to high resource
X
115
Red
P190
2
190
2
Engine speed/position sensor circuit lost-both of
two signals from the magnetic pickup sensor
X
116
Red
P156
3
156
3
Fuel timing pressure sensor circuit- voltage
above normal, or shorted to high resource
X
117
Red
P156
4
156
4
Fuel timing pressure sensor circuit- voltage
below normal, or shorted to low resource
X
118
Amber
P135
3
135
3
Fuel pump transmission pressure sensor circuit-
voltage above normal, or shorted to high
resource
X
119
Amber
P135
4
135
4
Fuel pump transmission pressure sensor circuit-
voltage below normal, or shorted to low
resource
X
121
Amber
P190
10
190
10
Engine speed/position sensor circuit lost-one of
two signals from the magnetic pickup sensor
X
122
Amber
P102
3
102
3
Intake manifold pressure sensor #1
circuit-voltage above normal or shorted to
high source
X
123
Amber
P102
4
102
4
Intake manifold #1 pressure sensor
circuit-voltage below normal, or shorted to low
source
X

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Dynapac F3030C and is the answer not in the manual?

Atlas Copco Dynapac F3030C Specifications

General IconGeneral
BrandAtlas Copco
ModelDynapac F3030C
CategoryConstruction Equipment
LanguageEnglish

Related product manuals