 To reset the device:
1. Open the Maintenance Actions page (see 'Basic Maintenance' on page 321).
2. Under the 'Reset Configuration' group, from the 'Burn To FLASH' drop-down list,
select one of the following options:
• Yes: The device's current configuration is saved (burned) to the flash memory
prior to reset (default).
• No: Resets the device without saving the current configuration to flash (discards
all unsaved modifications).
3. Under the 'Reset Configuration' group, from the 'Graceful Option' drop-down list,
select one of the following options:
• Yes: Reset starts only after the user-defined time in the 'Shutdown Timeout' field
(see Step 4) expires or after no more active traffic exists (the earliest thereof). In
addition, no new traffic is accepted.
• No: Reset starts regardless of traffic, and any existing traffic is terminated at
once.
4. In the 'Shutdown Timeout' field (relevant only if the 'Graceful Option' in the previous
step is set to Yes), enter the time after which the device resets. Note that if no traffic
exists and the time has not yet expired, the device resets.
5. Click the Reset button; a confirmation message box appears, requesting you to
confirm.
Figure 29-2: Reset Confirmation Message Box
6. Click OK to confirm device reset; if the parameter 'Graceful Option' is set to Yes (in
Step 3), the reset is delayed and a screen displaying the number of remaining calls
and time is displayed. When the device begins to reset, a message appears notifying
you of this.
29.2 Remotely Resetting Device using SIP NOTIFY
The device can be remotely reset upon the receipt of a SIP NOTIFY that includes an Event
header set to 'check-sync;reboot=true', as shown in the example below:
NOTIFY sip:<user>@<dsthost> SIP/2.0
To: sip:<user>@<dsthost>
From: sip:sipsak@<srchost>
CSeq: 10 NOTIFY
Call-ID: 1234@<srchost>
Event: check-sync;reboot=true

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-118
CategoryGateway
LanguageEnglish

Related product manuals