EasyManuals Logo
Home>AudioCodes>Gateway>MediaPack MP-118

AudioCodes MediaPack MP-118 User Manual

AudioCodes MediaPack MP-118
584 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #550 background imageLoading...
Page #550 background image
User's Manual 550 Document #: LTRT-65422
MP-11x & MP-124
Parameter Description
Web: Analog TTX Voltage
Level
EMS: TTX Voltage Level
[AnalogTTXVoltageLevel
]
Determines the metering signal/pulse voltage level (TTX).
ï‚§ [0] 0V = 0 Vrms sinusoidal bursts.
ï‚§ [1] 0.5V = (Default) 0.5 Vrms sinusoidal bursts.
ï‚§ [2] 1V = 1 Vrms sinusoidal bursts
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§ This parameter is applicable only to FXS interfaces.
Charge Codes Table
Web: Charge Codes Table
EMS: Charge Codes
[ChargeCode]
This table parameter configures metering tones and their time intervals
that the FXS interface generates to the Tel side.
The format of this parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
ï‚§ EndTime = Period (1 - 4) end time.
ï‚§ PulseInterval = Period (1 - 4) pulse interval.
ï‚§ PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Notes:
ï‚§ This parameter is applicable only to FXS interfaces.
ï‚§ To associate a configured Charge Code to an outgoing Tel-to-
IP call,
use the Tel to IP Routing.
ï‚§ To configure the Charge Codes table using the Web interface, see
Configuring Charge Codes Table on page 263.
43.10.8 Telephone Keypad Sequence Parameters
The telephony keypad sequence parameters are described in the table below.
Table 43-55: Telephone Keypad Sequence Parameters
Parameter Description
Web/EMS: Call Pickup Key
[KeyCallPickup]
Defines the keying sequence for performing a call pick-up. Call
pick-up allows the FXS endpoint to answer another telephone's
incoming call by pressing this user-defined sequence of digits.
When the user dials these digits (e.g., #77), the incoming call
from another phone is forwarded to the user's phone.
The valid value is a string of up to 15 characters (0-9, #, and *).

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-118
CategoryGateway
LanguageEnglish

Related product manuals