Detailed Test (Configurable): This test verifies the correct functioning of the different 
hardware components on the device. This test is done when the device is taken out of 
service (i.e., not in regular service for processing calls). The test is performed on 
startup when initialization of the device completes.   
To enable this test, set the ini file parameter, EnableDiagnostics to 1 or 2, and then 
reset the device. The Ready and Fail LEDs are lit while this test is running. Upon 
completion of the test and if the test fails, the device sends information on the test 
results of each hardware component to the Syslog server. 
The following hardware components are tested: 
•  Flash memory - when EnableDiagnostics = 1 or 2 
•  DSPs - when EnableDiagnostics = 1 or 2 
•  Physical Ethernet ports - when EnableDiagnostics = 1 or 2 
•  Analog interfaces - when EnableDiagnostics = 1 or 2 
 
 
Notes:  
•  To return the device to regular operation and service, disable the test by 
setting the ini file parameter, EnableDiagnostics to 0, and then reset the 
device. 
•  While the test is enabled, ignore errors sent to the Syslog server. 
 
  Startup Test (automatic): This hardware test has minor impact in real-time. While 
this test is executed, the regular operation of the device is disabled. If an error is 
detected, an error message is sent to the Syslog.