Detailed Test (Configurable): This test verifies the correct functioning of the different
hardware components on the device. This test is done when the device is taken out of
service (i.e., not in regular service for processing calls). The test is performed on
startup when initialization of the device completes.
To enable this test, set the ini file parameter, EnableDiagnostics to 1 or 2, and then
reset the device. The Ready and Fail LEDs are lit while this test is running. Upon
completion of the test and if the test fails, the device sends information on the test
results of each hardware component to the Syslog server.
The following hardware components are tested:
• Flash memory - when EnableDiagnostics = 1 or 2
• DSPs - when EnableDiagnostics = 1 or 2
• Physical Ethernet ports - when EnableDiagnostics = 1 or 2
• Analog interfaces - when EnableDiagnostics = 1 or 2
Notes:
• To return the device to regular operation and service, disable the test by
setting the ini file parameter, EnableDiagnostics to 0, and then reset the
device.
• While the test is enabled, ignore errors sent to the Syslog server.
Startup Test (automatic): This hardware test has minor impact in real-time. While
this test is executed, the regular operation of the device is disabled. If an error is
detected, an error message is sent to the Syslog.