Parameter Description
The valid range is -1 to 1,000. The default is -1 (i.e., not used).
Notes:
It is assumed that all Call Waiting Tones are defined in
sequence in the CPT file.
SIP Alert-Info header examples:
Alert-Info:<Bellcore-dr2>
Alert-Info:<http://…/Bellcore-dr2> (where "dr2" defines
call waiting tone #2)
The SIP INFO message is according to Broadsoft's
application server definition. Below is an example of such an
INFO message:
INFO sip:06@192.168.13.2:5060 SIP/2.0
Via:SIP/2.0/UDP
192.168.13.40:5060;branch=z9hG4bK040066422630
From:
<sip:4505656002@192.168.13.40:5060>;tag=1455352915
To: <sip:06@192.168.13.2:5060>
Call-ID:0010-0008@192.168.13.2
CSeq:342168303 INFO
Content-Length:28
Content-Type:application/broadsoft
play tone CallWaitingTone1
43.10.5.3 Call Forwarding Parameters
The call forwarding parameters are described in the table below.
Table 43-42: Call Forwarding Parameters
Parameter Description
Web: Enable Call Forward
[EnableForward]
Enables the Call Forwarding feature.
[0] Disable
[1] Enable (Default)
For FXS interfaces, the Call Forward table (FwdInfo parameter) must
be defined to use the Call Forward service. The device uses SIP
REFER messages for call forwarding.
Note: To use this service, the devices at both ends must support this
option.
Call Forwarding Table
Web: Call Forwarding Table
EMS: Analog Gateway
Provisioning > Tab: Call
Forward
[FwdInfo]
This table parameter configures call forwarding of IP-to-Tel calls (using
SIP 302 response) to other device ports or an IP destination, based on
the device's port to which the call was originally routed.
The format of this parameter is as follows:
[FwdInfo]
FORMAT FwdInfo_Index = FwdInfo_Type, FwdInfo_Destination,
FwdInfo_NoReplyTime;
[\FwdInfo]
Where,
Index = Port number, where 0 denotes Port 1.
For example:
Below configuration forwards calls originally destined to Port 1 to

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet