Parameters
None.
Clear Storage Array Firmware Pending Area
Description
This command deletes a previously downloaded firmware image or nonvolatile static random access
memory (NVSRAM) values from the pending area buffer.
CAUTION: As soon as you run this command, the contents of the existing pending area in the
storage array are deleted.
Syntax
clear storageArray firmwarePendingArea
Parameters
None.
Clear Storage Array Recovery Mode
Description
This command forces a storage array to exit recovery mode.
Syntax
clear storageArray recoveryMode
Notes
Recovery mode is entered during start-of-day operations when the system configuration is cleared and a
valid on-board backup is available. This mode is exited by either restoring the system configuration from
a backup location, or by clearing the existing on-board backups. While recovery mode is in force, a needs
attention condition is raised and the Recovery Guru becomes available from the user interface. However,
the system configuration is empty during recovery mode.
Clear Virtual Disk Reservations
Description
This command clears persistent virtual disk reservations.
152

Table of Contents

Other manuals for Dell PowerVault

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault and is the answer not in the manual?

Dell PowerVault Specifications

General IconGeneral
RAID Levels0, 1, 5, 6, 10, 50, 60
RAID SupportYes
Drive TypeSAS, SSD
InterfaceSAS, Fibre Channel, iSCSI
CategoryStorage
ConnectivityEthernet, Fibre Channel
ScalabilityYes
Operating System CompatibilityWindows, Linux, VMware
Management SoftwarePowerVault Manager, OpenManage

Related product manuals