EasyManuals Logo

Dell PowerVault User Manual

Dell PowerVault
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #368 background imageLoading...
Page #368 background image
Notes
This command runs a consistency check against a configuration database. All database records are
checked. Error data is written to a file in the data folder on disk automatically. You do not need to specify
an output file.
NOTE: Executing a consistency check with the diagnosticType parameter set to a value other
than filesystem, and with the sourceLocation parameter set to onboard, can cause the
operation to run for a long time. This can have adverse effects on host I/O processing. This
operation should be done only under direction from the support organization.
Upon completion of the diagnostic test, the controller firmware returns one of these results:
• Diagnosis completed without errors. No ZIP file created.
• Diagnosis completed with errors. Refer to the ZIP file created at:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
If the diagnostic test detects an inconsistency in the configuration database, the RAID controller module
firmware performs these actions:
• Returns a description of the inconsistency
• Saves a ZIP file containing raw binary data
The RAID controller module firmware saves the ZIP file to this location:...\Install_dir\data
\FirmwareUpgradeReports\timestamp_buildNo.zip
You can use the binary data to help determine the cause of the problem, or you can send the file
containing the binary data to a Technical Support representative.
To stop the database configuration diagnostic test, use the stop storageArray
configDbDiagnostic command.
In addition, you can start the database configuration diagnostic test through the storage management
software GUI; however, you cannot stop the database configuration diagnostic test through the storage
management software GUI. If you want to stop a running diagnostic test, you must use the stop
storageArray configDbDiagnostic command.
Start Storage Array iSCSI Refresh
Description
This command initiates a refresh of the network address information for the iSNS server. If the DHCP
server is marginal or unresponsive, the refresh operation can take from 2 to 3 minutes to complete.
NOTE: This command is for IPv4 only.
Syntax
start storageArray isnsServerRefresh
Parameters
None.
368

Table of Contents

Other manuals for Dell PowerVault

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault and is the answer not in the manual?

Dell PowerVault Specifications

General IconGeneral
RAID Levels0, 1, 5, 6, 10, 50, 60
RAID SupportYes
Drive TypeSAS, SSD
InterfaceSAS, Fibre Channel, iSCSI
CategoryStorage
ConnectivityEthernet, Fibre Channel
ScalabilityYes
Operating System CompatibilityWindows, Linux, VMware
Management SoftwarePowerVault Manager, OpenManage

Related product manuals