Safety considerations
Versana Balance – Basic Service Manual System view 1-17
5808768-100 English Rev.9
1-6-4 Mechanical safety
WARNING
While the software install procedure is designed to preserve
data, you should save any patient data, images, system setups
to removable media or hardcopy before doing a software
upgrade.
WARNING
Ultrasound probes are highly sensitive medical instruments
that can easily be damaged by improper handling. Use care
when handling and protect from damage when not in use. Do
NOT use a damaged or defective probe. Failure to follow these
precautions can result in serious injury and equipment
damage.
WARNING
Never use a probe that has fallen to the floor. Even if it looks
OK, it may be damaged.
WARNING
When the Ultrasound system is raised for a repair or moved
along any incline, use extreme caution since it may become
unstable and tip over.
CAUTION
Take extra care when moving the system.
The Versana Balance weighs approximately 50 kg (100 lbs) or
more, depending on installed peripherals, when ready for use.
To avoid possible injury and equipment damage when
transporting from one area of use to another:
Be sure the pathway is clear.
Limit movement to a slow careful walk.
Use two or more persons to move the equipment on
inclines or long distance.
CAUTION
Before you move or transport the Ultrasound system, make
sure to lock the monitor arm firmly and flip down the monitor to
prevent damage to the Ultrasound system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Versana Balance and is the answer not in the manual?

GE Versana Balance Specifications

General IconGeneral
CategoryUltrasound System
Doppler ModesColor Doppler, Power Doppler, Pulsed Wave Doppler, Continuous Wave Doppler
Power Requirements100-240 V AC, 50/60 Hz
DICOM CompatibilityYes
Wireless ConnectivityOptional
DisplayLED
Transducersconvex, linear, phased array
Image StorageUSB
ConnectivityUSB, HDMI, Ethernet, DICOM
ApplicationsObstetrics, Gynecology, Cardiology, Vascular, Urology
Imaging Modes2D, M-Mode, 3D/4D
Operating Temperature10°C to 40°C
Storage Temperature-20°C to +60°C
Humidity Range20% to 80% (non-condensing)
Display Size15.6 inches
Transducer Ports3 active transducer ports