21
ENGLISH
7. SETTING PROCEDURE OF THE SEWING DATA
The standard patterns of pattern Nos. 90 to 99 can change the sewing speed and the thread tension,
however, cannot change the sewing shape. When changing the shape , it is necessary to copy the
shape to another pattern No. [See item (20) Copy destination No. on page 38.]
1) Confirm that sewing LED
has gone out.
When it lights up, press [READY ] key
to
make it go out.
2) Display the pattern No. you desire to change the
data .
3) Press the respective setting keys of the parts
desired to be changed and display the data.
[SHAPE ] key
[LENGTH ] key
[CB ] key
[CA ] key
[STITCHES ] key
[STITCHES ] key
[SPACE ] key
[SPACE ] key
[LENGTH ] key
[STITCHES ] key
[OFFSET ] key
[MAX ] key
[EYELET ] key
[FUNCTION F1 ] key
[FUNCTION F2 ] key
4)
Press [RIGHT ] key
or [RIGHT ] key
to
set the respective data.
5) Press [READY ] key
to light up sewing LED
and the data are stored in memory.
When changing the pattern No. without pressing [READY ] key or turning OFF the power, the data
are not stored in memory.
6)
When the memory switch No. 20 is set to “1”, change of data setting in the above step 4) can be prohibited.
(See the item of the memory switch on page 68.)
The data No. is stated in 2-digit LED
and the example of the set value is stated in 4-digit LED
as
shown below. The setting range is stated in the respective sentences.