Appendix N Remapping inputs & outputs
This feature allows one to remap the mentioned input and output signals to a specific input or output pin on X03.
The inputs for print request and product detect cannot be remapped. Remapping the general output is possible,
but the default output can switch more power than the other outputs (default general error can switch 24V / 2A,
the other outputs can switch 24V / 300mA).
These are the default settings:
Outputs:
X03-16A-7B Busy
X03-14A-5B Ink Out
X03-15A-6B Ink Low
X03-18A-9B General Error
Inputs
X03-19A-20B Inhibit
X03-13A-4B Trigger