EasyManuals Logo

Lenze i55 Series User Manual

Lenze i55 Series
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #425 background imageLoading...
Page #425 background image
Parameter Name / value range / [default seng] Info
0x2602:001
(P708.01)
Keypad setup: CTRL & F/R key setup
(Keypad setup: CTRL&F/R keys)
From version 03.00
Disable/enable CTRL and F/R key of the keypad.
0 CTRL & F/R Disable
1 CTRL & F/R Enable
2 CTRL Enable F/R Disable
3 CTRL Disable F/R Enable
0x2602:002
(P708.02)
Keypad setup: Select rotaonal direcon
(Keypad setup: Select rot.dir.)
From version 03.00
Instructed direcon of rotaon if local keypad control is acve.
If the local keypad control is acve, this seng can be directly
changed via the keypad key
R
F
if the key in 0x2602:001 (P708.01)
has not been disabled.
When the remote control is changed over to local keypad control and
vice versa, this parameter is set to "Forward [0]".
0 Forward
1 Reverse
0x2602:003
(P708.03)
Keypad setup: Keypad Full Control
(Keypad setup: Keypad Full Ctrl)
From version 03.00
Acvate/deacvate full keypad control.
This seng can be changed directly via the keypad key
CTRL
if the
key in 0x2602:001 (P708.01) has not been disabled.
When the control mode is changed over, the motor is stopped and the
"Forward" direcon of rotaon is set.
0 O
1 On
Addional funcons
Keypad
Keypad - Conguraon of R/F and CTRL buons