EasyManuals Logo

Lenze i55 Series User Manual

Lenze i55 Series
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #620 background imageLoading...
Page #620 background image
14.16.2 Analog output 2
Sengs for analog input 2.
Precondions
Control Unit (CU) with applicaon I/O
Details
The analog output 2 is controlled with the signal selected in 0x263A:002 (P441.02).
The following sengs are possible for the analog output:
Denion of the signal range
Denion of the output range
AO2
0x263A:0010x263A 003:
0x263A 004:
X3
0x2DAB:001
V/mA
0x263A:002
0x2DAB:002
[V]
[mA]
Min
Max
Signal
Diagnosc parameters:
The current output voltage is displayed in 0x2DAB:002 (P113.02).
The actual output current is displayed in 0x2DAB:001 (P113.01).
For further details and conguraon examples, see chapter "Analog output 1". ^ 617
Parameter Name / value range / [default seng] Info
0x263A:001
(P441.01)
Analog output 2: Output range
(Analog output 2: AO2 outp. range)
Only available for applicaon I/O.
Denion of the output range.
0 Inhibited
1 0 ... 10 VDC
2 0 ... 5 VDC
3 2 ... 10 VDC
4 4 ... 20 mA
5 0 ... 20 mA
0x263A:002
(P441.02)
Analog output 2: Funcon
(Analog output 2: AO2 funcon)
Only available for applicaon I/O.
Selecon of the signal to be shown at analog output 2.
0 Not acve No output signal.
1 Output frequency Actual output frequency (resoluon: 0.1 Hz).
2 Frequency setpoint Actual frequency setpoint (resoluon: 0.1 Hz).
3 Analog input 1 Input signal of analog input 1 (resoluon: 0.1 %).
4 Analog input 2 Input signal of analog input 2 (resoluon: 0.1 %).
5 Motor current Actual motor current (resoluon: 0.1 A).
6 Output power Actual output power (resoluon: 0.001 kW).
7 Torque actual value Torque actual value (resoluon: 0.1 %).
100 % ≡ permissible maximum torque 0x6072 (P326.00)
10 Sequencer controlled (from version 03.00) Voltage value which has been set for the currently executed sequencer
segment (resoluon: 0.01 V).
4Sequencer ^ 504
20 NetWordIN3 Actual value of the NetWordIN3 data word (resoluon: 0.1 %).
4Further process data ^ 251
21 NetWordIN4 Actual value of the NetWordIN4 data word (resoluon: 0.1 %).
4Further process data ^ 251
201 Internal value (from version 05.00) Internal values of the manufacturer.
202 Internal value (from version 05.00)
203 Internal value (from version 05.00)
204 Internal value (from version 05.00)
205 Internal value (from version 05.00)
206 Internal value (from version 05.00)
Flexible I/O conguraon
Conguraon of analog outputs
Analog output 2
620

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55 Series and is the answer not in the manual?

Lenze i55 Series Specifications

General IconGeneral
BrandLenze
Modeli55 Series
CategoryInverter
LanguageEnglish

Related product manuals