Scalar DLC Reference Guide 105
Robot2 coordinate Supplied The drive coordinate in Robot2 (None means the slot
is assigned to another robot). Refer to Element
Addressing on page 244
LSCI coordinate Supplied Drive LCSI coordinate. Refer to Element Addressing
on page 244.
Current cartridge Supplied A cartridge contained in the slot, if any.
State Supplied Drive state (empty/occupied).
Number of mounts Supplied A total number of mounts executed into the drive.
Time (ms) Enter The cleaning time for the drive.
Clean pool Select A pool that is used by clean manager to get the
cleaning cartridges.
Automatic cleaning Check Configure auto-cleaning. If checked, the Max Use field
is editable.
Max Use Supplied Shows how long the drive could be used without
cleaning (number of mounts between cleanings).
Dismount
management
Check Configure the dismount manager. If checked, the
Delay and Loops fields are editable.
Delay (ms) Supplied A time the drive requires to unload the cartridge.
Loops Supplied Number of retries if the drive does not unload the
cartridge.
Owner Select A slot owner (client). The reserved slot can be used
only by its owner.
None means the slot is not reserved.
Exclusive reservation Supplied The reservation may be either normal (another owner
can un-reserve the slot) or exclusive (only the owner
can change the reservation).
Update Click Save the slot properties after edit.
Reset Alarm flag Click Remove Alarm flag (active only when the slot is in
Alarm state).
Refresh Alarm flag Click Refresh Management GUI for Alarm.
Help Click Open online help for the current pane.
Note
If the DAS interface is being used, the drives are to be named according to the DAS
standards. ADIC recommends using names no more than 9 alphanumeric characters
long and beginning with a letter.
Field/Button Icon Operation Description