Scalar DLC Reference Guide 245
Figure 189 Element Addressing (dual-aisle library)
The Management GUI also indicates the LSCI coordinates used by ROBAR and (sometimes) DAS
software.
The LSCI coordinates consists of 5 character pairs. The first four characters signify the ‘name' or the number
of the device. The third pair of characters signifies the column in which the position is located. The fourth
pair of characters signifies the row of the position and the last two characters show the position in this row.
These coordinates are mapped from the coordinates of the physical library by the following way:
• Device type and number (four symbols): for example, LW01 means ‘storage shelve number 1’,
D006 means ‘drive number 6’, etc.
• Column-row-position (six digits): for drives always 000000, for other types of slots something like
011006 or 120804.
Example: the LSCI coordinate “LW02060210“ means “a slot that can be fount at storage shelve 2, rack 6,
column 2, position 10“.
Application Notes
This section holds various supplemental information concerning different parts of the Scalar DLC software
and clients as well.
• Media Type
s on page 246.
• S
torage Types on page 247.
Table 30 Element Mapping (Dual-aisle libraries)
Section
Robot1 Start
Coordinate
Robot2 Start
Coordinate
Scalar DLC Start Physical
Coordinate
I/E
16 None 1024 (Robot1 I/E)
None 16 2048 (Robot2 I/E)
Drive
256 None 4096 (Robot1 drives)
None 256 8192 (Robot2 drives)
Storage
4096
None 32768 (Robot1 storage)
4096
16384 (shared storage)
None 49152 (Robot2 storage)