Motion synchronous actions
10.5 Technology cycles
Job planning
628 Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
Examples
Example 1: Lock synchronized actions (LOCK)
Program code
N100 ID=1 WHENEVER $A_IN[1]==1 DO M130
...
N200 ID=2 WHENEVER $A_IN[2]==1 DO LOCK(1)
Example 2: Unlock synchronized actions (UNLOCK)
Program code
N100 ID=1 WHENEVER $A_IN[1]==1 DO M130
...
N200 ID=2 WHENEVER $A_IN[2]==1 DO LOCK(1)
...
N250 ID=3 WHENEVER $A_IN[3]==1 DO UNLOCK(1)
Example 3: Interrupt technology cycle (RESET)
Program code
N100 ID=1 WHENEVER $A_IN[1]==1 DO M130
...
N200 ID=2 WHENEVER $A_IN[2]==1 DO RESET(1)