Engineering and remote access
7.10 Parameter write behavior of the SITOP PSU8600
Power supply system SITOP PSU8600
350 Manual, 09.2018, A5E36758446-5-76
Retentively saved PROFINET data sets in the RUN mode
48 0 1 PROFIenergy values
Reading PROFIenergy settings of the
36 bytes
Writing Adjustable PROFIenergy parameters of
the SITOP PSU8600.
49 0 1 PROFIenergy channel
list
Reading /
writing
PROFIenergy pause configuration of
the power supply system (outputs,
which are switched off during a
8 bytes
53 0 1 Web server values Reading Web server settings of the
6 bytes
Writing Adjustable parameters for the web
server of the SITOP PSU8600.
54 0 1 OPC UA values Reading OPC UA settings of the
4 bytes
Writing Adjustable parameters for the OPC UA
interface of the
55 0 1 NTP client settings Reading NTP client settings of the
66 bytes
Writing Adjustable parameters for the
NTP client of the SITOP PSU8600
56 0 1 NTP client status Reading Time of the last synchronization - time
of the next synchronization
40 bytes
57 0 1 ProfiNet security en-
hancement settings
Reading Parameters relating to security 2 bytes
Writing Adjustable parameters relating to secu-
Index 48: PROFIenergy settings (reading)
Enable PROFIenergy on this device
Enable PROFIenergy on this device
Power consumption in saving mode [kW]
Power consumption during operation [kW]
Energy consumption to pause [kWh]
Energy consumption to operation [kWh]