Parameter Details
2
2.2 A: Initialization Parameters
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 155
A1-11: Firmware Update Lock
No.
(Hex.)
Name Description
Default
(Range)
A1-11
(111D)
Expert
Firmware Update Lock
Protects the drive firmware. When you enable the protection, you cannot update the drive firmware.
0
(0, 1)
0 : Disabled
Lock is disabled.
1 : Enabled
Lock is enabled.
A1-12: Bluetooth ID
No.
(Hex.)
Name Description
Default
(Range)
A1-12
(1564)
Bluetooth ID
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.
-
(0000 - 9999)
A2: User Parameters
You can register frequently used parameters and recently changed parameters here to access them quickly. Use Setup
Mode to show the saved parameters.
A2-01 to A2-32: User Parameters 1 to 32
No.
(Hex.)
Name Description
Default
(Range)
A2-01 to A2-32
(0106 - 0125)
User Parameters 1 to 32
You can select a maximum of 32 parameters for the drive and save the values to parameters A2-01 to
A2-32. Use Setup Mode to show the saved parameters. You can immediately access these saved
parameters.
Parameters in General-
Purpose Setup Mode
(Determined by A1-06)
Note:
When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.
You must set A1-01 = 1 [Access Level Selection = User Parameters] to access parameters A2-01 to A2-32.
When A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/Disabled wDigital Input], the drive saves qx-xx
[DriveWorksEZ Parameters] to A2-01 to A2-32.
The drive saves these parameters to A2-01 to A2-32.
The drive saves a maximum of 32 parameters.
Note:
Set A1-01 = 2 [Advanced Level] or A1-01 = 3 [Expert Level] to save the necessary parameters.
The drive automatically saves changed parameters to A2-17 to A2-32.
Note:
Set A2-33 = 1 [User Parameter Auto Selection = Enabled].
A2-33: User Parameter Auto Selection
No.
(Hex.)
Name Description
Default
(Range)
A2-33
(0126)
User Parameter Auto
Selection
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User Parameters 17 to
32].
Determined by A1-06
(0, 1)
0 : Disabled: Manual Entry Required
Set User Parameters manually.
1 : Enabled: Auto Save Recent Parms
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA GA500 GA50U Series and is the answer not in the manual?

YASKAWA GA500 GA50U Series Specifications

General IconGeneral
TypeDC Drive
ManufacturerYASKAWA
DimensionsVaries by model
WeightVaries by model
SeriesGA50U
Control MethodVector Control, V/f Control
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Short Circuit
Communication InterfaceEtherNet/IP
Ambient Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
Storage Temperature-20°C to +60°C (-4°F to +140°F)