EasyManuals Logo

YASKAWA GA500 GA50U Series User Manual

YASKAWA GA500 GA50U Series
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #517 background imageLoading...
Page #517 background image
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 517
Index
Numerics
24 V power supply
Power supply input terminals ..................................... 505
A
Acceleration and deceleration times
Switching by external input ....................................... 203
Switching by output frequency ................................... 204
Switcing by Motor 2 Selection commands...................... 204
Acceleration time
Parameter ............................................................ 203
Unit of measurement setting ...................................... 206
Adjustment of control functionality .................................. 481
AFR
Parameter ............................................................ 406
Ambient Temperature Setting
Parameter ............................................................ 400
Analog input
Function selection for terminals A1 and A2 .................... 332
Analog Output
Gain/Bias Adjustment ............................................. 343
Monitor Parameter Selection...................................... 343
Signal Level Selection ............................................. 343
Terminal AM Monitor Selection ................................. 344
Application Preset....................................................... 149
Operation ............................................................ 471
ASR
Fine tuning .......................................................... 217
Parameter ............................................................ 215
Vector Control Adjustment Procedure........................... 216
Auto-Tuning ....................................................... 472, 475
ASR and Inertia Tuning Parameters ............................. 455
Induction Motor .................................................... 472
Induction Motor Parameters ...................................... 449
PM Motor Parameters.............................................. 452
PM motors........................................................... 473
Precautions .......................................................... 476
Rotational Auto-Tuning Precautions............................. 477
Stationary Auto-Tuning for Line-to-Line Resistance
precautions.................................................... 478
Stationary Auto-Tuning Precautions............................. 477
Stator resistance Auto-Tuning precautions...................... 478
B
Backup
Parameters (drive to keypad) ..................................... 468
Backup function ......................................................... 439
Base frequency
Parameter ............................................................ 248
Base Frequency
Motor 2 Parameters ................................................ 253
Base voltage
Motor 2 parameters................................................. 254
Parameter ............................................................ 249
Bi-Directional function ................................................. 238
Braking Resistor
Protection Functions ............................................... 397
bUS
Detection condition settings....................................... 275
Detection conditions ............................................... 271
Operation Selection after Detection.............................. 270
C
Capacitor Maintenance Setting........................................ 441
Carrier frequency........................................................ 221
Parameter ............................................................ 220
CE
Detection Selection................................................. 346
Detection time ...................................................... 347
Operation Selection after Detection.............................. 346
Checklist
Test run .............................................................. 486
Communication option
Parameter ............................................................ 264
Control circuit terminals
Configuration of terminal block .................................. 506
I/O terminals function selection switches ....................... 506
Terminal functions ................................................. 503
Wiring................................................................ 502
Control method
Selection ............................................................. 146
Cooling Fan
Activation Conditions Setting .................................... 399
Off Delay Timer .................................................... 400
Cumulative Operation TimeSetting................................... 440
Current Detection Speed Search ...................................... 171
D
DC Injection Braking
Parameter ............................................................ 167
Deceleration time
Parameter ............................................................ 203
Unit of measurement setting ...................................... 206
Delete
Delete Backed-up Parameters..................................... 470
Derating
Ambient Temperature Setting..................................... 400
Enclosure Type ..................................................... 401
External Cooling Fin ............................................... 401
Finless................................................................ 401
Side-by-side ......................................................... 401
dEv
Detection level ...................................................... 264
Detection time ...................................................... 264
Operation Selection after Detection.............................. 263
Digital character ......................................................... 466
DIP switch ............................................................... 506
Down 2 command
Parameter ...................................................... 233, 238
Down command ................................................... 294, 296
Parameter ...................................................... 233, 238
Drive
Initialization......................................................... 147
Initialize Parameters ............................................... 147
Drive Mode Unit Monitor Select...................................... 428
Drive Model Selection.................................................. 436
Dwell function
Parameter ............................................................ 197
E
E5
Operation Selection after Detection.............................. 274
EF0
Detection conditions ............................................... 271

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA GA500 GA50U Series and is the answer not in the manual?

YASKAWA GA500 GA50U Series Specifications

General IconGeneral
TypeDC Drive
ManufacturerYASKAWA
DimensionsVaries by model
WeightVaries by model
SeriesGA50U
Control MethodVector Control, V/f Control
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Short Circuit
Communication InterfaceEtherNet/IP
Ambient Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
Storage Temperature-20°C to +60°C (-4°F to +140°F)