RSTP Configuration 181
You can use the following command to set the multiple value of hello time of a
specified bridge.
Perform the following configurations in System View.
Tab le 179 Set Timeout Factor of the Bridge
It is recommended to set 5, 6 or 7 as the value of multiple in the steady network.
By default, the multiple value of hello time of the bridge is 3.
Specifying the
Maximum Transmission
Rate of STP Packets on a
Port
The maximum transmission rate of STP packets on an Ethernet port is dependent
on the physical status of the port and the network architecture. You can specify it
as needed.
You can specify the maximum transmission rate on a port by using the following
commands.
Perform the following configuration in Ethernet Interface View.
Tab le 180 Specifying the Maximum Transmission Rate of STP Packets on a Port
Notably, though a higher transmission rate is introduced at larger Packetnum,
more Switch resources are consequently occupied. It is therefore recommended to
use the default value.
By default, an Ethernet port can transmit at most 3 STP packets within one Hello
Time.
Set Specified Port to be
an EdgePort
EdgePort is not connected to any Switch directly or indirectly via the connected
network.
You can use the following command to set a specified port as an EdgePort.
Perform the following configurations in Ethernet Port View.
Tab le 181 Set Specified Port as the EdgePort
In the process of recalculating the spanning tree, the EdgePort can transfer to the
forwarding state directly and reduce unnecessary transition time. If the current
Operation Command
Set the multiple value of hello time of a specified bridge stp timeout-factor number
Restore the default multiple value of hello time undo stp timeout-factor
Operation Command
Specify the maximum transmission rate of STP
packets on a port
stp transmit-limit packetnum
Restore the default transmission rate of STP
packets on a port
undo stp transmit-limit
Operation Command
Set a specified port as an EdgePort or a non-EdgePort stp edged-port { enable |
disable }
Set the specified port as the non-EdgePort, as defaulted undo stp edged-port

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3Com Switch 4500 26-Port and is the answer not in the manual?

3Com Switch 4500 26-Port Specifications

General IconGeneral
Brand3Com
ModelSwitch 4500 26-Port
CategorySwitch
LanguageEnglish

Related product manuals