3 Maintenance
3.5.3. Rust preventive, bearing axis 4 (Foundry Prime)
2073HAC023082-001 Revision: E
© Copyright 2004-2008 ABB. All rights reserved.
3.5.3. Rust preventive, bearing axis 4 (Foundry Prime)
Overview
The bearing axis 4 is located as shown in the illustration below.
xx0500002869
Required equipment
Procedure
The following procedure details how to grease the bearing axis 1.
A Plastic cover
B Plastic ring
Equipment Art. no. Note
Brush
Rust preventive 3HAC026621-001 Equivalent:
• Mercasol 3106
Standard toolkit The contents are defined in
section Standard toolkit on
page 436, in part 2 of the
Product manual.
Other tools and procedures
may be required. See
references to these
procedures in the step-by-
step instructions below.
These procedures include
references to the tools
required.
Action Note/Illustration
1. Put the manipulator in a suitable
position.
Continues on next page