10.17 AC output specifications (Option for 180 and 60)
Parameter Specification
AC output voltage range (3 phase) 400 V AC
Maximum AC output power 22 kW
Connection standard
• Type 2 socket
• Type 2 socket with shutter
According to IEC 62196-1 and IEC 62196-2
Current for MID certified models 0.25-5 (32) A
10.18 Power consumption
10.18.1 General specifications
Parameter Specification
Standby power 80 W, excluding the heater
Note: The heater will operate daily when the outside air reaches the
dew point, to avoid condensation inside the cabinet. When the heater
operaters, the heater will use most of the required standby power.
10.18.2 Terra 360
Parameter Specification [kVA)
Power consumption (normal operation) 390
10.18.3 Terra 180
Parameter Specification [kVA)
Power consumption (normal operation) 195
10.18.4 Terra 60
Parameter Specification [kVA)
Power consumption (normal operation) 98
10.19 Cooling system specifications
Parameter Specification
System -5
Controls ABB cooling system controller with full
control and full diagnostics
Technical data
124 9AKK108467A6398-EN | 002