Parameter Specification
Cooling fluid Huber+Suhner CP3-002
Readily biodegradable, aligns with
OECD criteria
German Water Hazard Class 1 (slight-
ly hazardous to water)
No indication of bioaccumulation po-
tential
Low mobility in soil
Fluid couplers Screw-type connectors
Spill containment Tank integrated in side panel on the LED
strip side
10.20 External residual current device specifications
10.20.1 External residual current device (Terra 360)
Id
A
B
C
D
E
A 3 Phase MV
B MV switch
C 3 Phase 400 Vac
D Automatic circuit breaker
E Residual current breaker type B
Technical data
9AKK108467A6398-EN | 002 125