Serial port Configure Modem emulator mode
Digi Connect EZ Mini User Guide
143
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in Use Digi Remote Manager to view and manage your
device.
b. Click the Device ID.
c. Click Settings.
d. Click to expand Config.
Local Web UI:
a. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click to expand the name of the port that you want to configure, for example, Port 1.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select Modem emulator. The default is Login.
5. (Optional) For Label, enter a label that will be used when referring to this port.
6. For Baud rate, select the baud rate used by the device to which you want to connect. The
default is 9600.
7. For Data bits, select the number of data bits used by the device to which you want to connect.
The default is 8.
8. For Parity, select the type of parity used by the device to which you want to connect. The
default is None.
9. For Stop bits, select the number of stop bits used by the device to which you want to connect.
The default is 1
10. For Flow control, select the type of flow control used by the device to which you want to
connect. The default is None.
11. For Idle timeout, type the amount of time that the active session can be idle before the
session is disconnected.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Idle timeout to ten minutes, enter 10m or 600s.
12. For Escape character, type the character to use in the escape sequence. Enter this character
three times, followed by the escape delay and then an ATcommand to switch from data mode
to command mode. The default is the plus sign (+).
13. For Escape delay, type the delay between the escape sequence and an ATcommand to switch
from data mode to command mode. The default is 1s.
14. For Auto-answer rings, type the number of rings to wait before auto-answering. Enter 0 (zero)
to disable auto-answering.