Interfaces Wide Area Networks (WANs)
Digi Connect EZ Mini User Guide
69
(config)> network interface my_wan surelink advanced delayed_start 600s
(config)>
The default is 300s.
g. Set the time to add to the test interval when restarting the list of actions. This option is
capped at 15 minutes.
(config)> network interface my_wan advanced backoff_interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set backoff_interval to ten minutes, enter either 10m or 600s:
(config)> network interface my_wan advanced backoff_interval 600s
(config)>
The default is 300 seconds.
h. The interface_gateway parameter is used by the Interface gateway Ping test as the
endpoint for traceroute to use to determine the interface gateway. The default is 8.8.8.8,
and should only be changed if this IP address is not accessible due to networking issues. To
set to an alternate host:
(config)> network interface my_wan advanced interface_gateway
hostname/IP_address
(config)>
8. Save the configuration and apply the change:
(config network interface my_wan ipv4 surelink)> save
Configuration saved.
>
9. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Configure the device to reboot when a failure is detected
Using SureLink, you can configure the Connect EZ device to reboot when it has determined that an
interface has failed.
Required configuration items
n Enable SureLink.
n Enable device reboot upon interface failure.
n The type of tests to be performed:
l Ping test: Uses ICMP to determine connectivity. The default behavior is to ping the
interface gateway, which means that an initial traceroute is sent to the hostname or IP
address configured in the SureLink advanced settings, and then the first hop in that route
is used for the ping test.