7.5.9 Replacing the 10x 2.5-inch HDD backplane
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
â–¶
"Locating the defective server" on page 45.
â–¶
If applicable, "Removing the front cover with lock" on page
48.
â–¶
"Shutting down the server" on page 48.
â–¶
"Disconnecting the power cord" on page 49.
â–¶
"Getting access to the component" on page 52.
â–¶
Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page 143.
CAUTION
The HDD/SSD modules need not to be removed.
â–¶
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
â–¶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD dummy module" on page
140.
â–¶
If applicable, remove the internal RAID riser module, see "Removing the
internal RAID riser module (option)" on page
153.
Hard disk drive (HDD) / solid state disk (SSD)
158 Upgrade and Maintenance Manual RX2530 M6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2530 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2530 M6 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2530 M6
CategoryServer
LanguageEnglish

Related product manuals