5.3.7 Enabling replaced components in the BIOS
When an expansion card fails, the defective component will be set to Disabled
or Failed in the BIOS. The server will then reboot with only the intact hardware
components remaining in the system configuration.
Communication between BIOS and iRMC temporarily failed during the
POST.
Booting to execute iRMC Emergency Flash.
In this cases, the defective component needs to be reenabled in the BIOS after
replacing it.
Enter the BIOS.
Select the Configuration
menu.
Select the status menu of the desired component:
Select PCI Status for expansion cards.
Reset replaced components to Enabled.
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.3.8 Verifying the system time settings
This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
Basic software procedures
88 Upgrade and Maintenance Manual RX2530 M6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2530 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2530 M6 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2530 M6
CategoryServer
LanguageEnglish

Related product manuals