Diagnostics 282
Outputs
This test allows the activation of all optically-isolated discrete outputs in the control. Each Output‟s
state can be changed by selecting the desired output with the PREV and NEXT keys and then
pressing the SPACE key. The current state of each output, On or Off, is displayed to the left of the
output name. Below is an output screen with all of the outputs Off.
Warning: When manually activating the control‟s outputs, Machine, Torch and Marker motion may
occur and the cutting device may activate.
Outputs displayed with a white background allow for the Output name to be selected by the user. To
change the output name, use the Previous/Next arrow key to highlight the desired output and type the
new text for the output name. The output can then be connected to the control and used as
commanded in the part program. Example: The EIA M22 and M23 code will turn on and off output
12.
Note: The number and name of the Outputs will vary due to control software and hardware
configurations.

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals