Password Setups 312
Rotate Acceleration Rate
This parameter allows the operator to set the acceleration rate for smooth and stable movement of
the contoured bevel head. The higher the acceleration rate, the quicker the Rotate Axis will get up to
speed. The lower the acceleration rate, the smoother the machine will position the cutting device.
Values are entered in Rev/ Sec^2.
Maximum Rotate Speed
Enter the maximum speed for the Rotate Axis rotation in RPM.
Rotate High Jog Speed
Enter a value for the desired Rotate Axis High Jog Speed.
Rotate Low Jog Speed
Enter a value for the desired Rotate Axis Low Jog Speed.
Tilt Acceleration Rate
This parameter allows the operator to set the acceleration rate for smooth and stable movement of
the contoured bevel head. The higher the acceleration rate the quicker the Tilt Axis will get up to
speed. The lower the acceleration rate the smoother the machine will position the cutting device.
Values are entered in Rev/ Sec^2.
Maximum Tilt Speed
Enter the maximum speed for the Tilt Axis in RPM.
Tilt High Jog Speed
Enter a value for the desired Tilt Axis High Jog Speed.
Tilt Low Jog Speed
Enter a value for the desired Tilt Axis Low Jog Speed.
Torch Height Disable Feature
The Torch Height Disable Feature is used to activate the Torch Height Disable output and “freeze” or
disable the automatic adjustment of the Automated Torch Height Control system and prevent diving
or crashing of the torch in corners. Note: The Dual Grid/THC feature must first be enabled in the
Plasma Setups screen.
This output is activated by the control based on the values of Plasma Hi/Lo % of Cut Speed, Plasma
Distance to Corner and Plasma Distance from Corner setup parameters. When any one of these
conditions is met, the Torch Height Disable feature will be implemented. The definition of a corner is
based on the tangent angle in the Special Password screen and the value of the Plasma Hi/Lo speed.
Tangent Angle
This parameter is used to set degree of the tangent angle for control motion. Segments within a part
that intersect at angles greater than the selected tangent angle will decel to zero or minimum corner

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals